  data sheet zfk, zry general measuring object: oxygen contained in noncombustible gas measuring principle: direct-insertion zirconia system measuring range: 0 to 5, 10 or 25 vol% o 2 (changed by internal set pin) repeatability: within 1.0% of full scale linearity: 2% of full scale response time: within 7sec for 90% response (from calibration gas inlet) power supply: 100, 115, 220 or 230v ac, 50/60hz power consumption: (approx.) 15 + 50va (at steady state) 15 + 200va (at start) warmup time: approx. 15min this oxygen analyzer is used to continuously measure oxygen concentration in combustion exhaust gas of industrial boilers or furnaces, and is ideally suited for combustion moni- toring and control. the detector (zfk) used with the analyzer is directly inserted into the objects measured, eliminating the need for a sampling device and provides quick response. the converter (zry) features 3 measuring ranges, one touch calibration and nema4 housing. comparing to the current converter (zrm) , this zry is recognized as economical type with simple functions. 1. sampling device is unnecessary gas sampling devices such as a gas aspirator, a dehu- midifier, etc. are unnecessary because of use of direct- insertion type detector. 2. high speed response the adoption of a flow guide tube utilizing the flow of the measured gas assures quick response (less than 7sec). 3. dust-tight and water-proof housing aluminum die casting housing of converter satisfies nema4 and ip65 standard. 4. 3-measuring ranges and one touch calibration the converter has 0-5, 10, 25 vol% 3 ranges easily changed by pin connection and zero and span are simply calibrated by key operation. in-situ zirconia oxygen analyzer < zircomat-c > features specifications oxygen detector (zfk2, 5) measuring detector: for general-use: zfk2 for corrosive gas: zfk5 measured gas temperature: flow guide tube system; ?0 to +600 c measured gas pressure: ? to +3kpa flow guide tube: flange; jis5k 65a ff (jis5k-80aff for high particulate gas) insertion length; 0.3, 0.5, 0.75, 1m (0.8m for high particulate gas) ambient temperature: ?0 to +60 c for cable section 125 c or less at detector flange surface with power applied structure: dust/rain-proof structure(iec ip55 equivalent) filter: alumina(filtering accuracy 50 m) and quartz paper main materials of gas-contacting parts: general-use detector(zfk 2); zirconia, sus316, platinum, sus304 anticorrosive detector(zfk 5); zirconia, tita-nium, platinum, sus316 flow guide tube; sus304 or sus316 general-use detector converter date EDSX3-119B mer. 6, 2007
zfk, zry 2 the product conforms to the requirements of the electromagnetic compatibility directive 89/336/eec as detailed within the technical construction file number tz737041. the applicable standards used to demonstrate compliance are : en 55011 : 1992 classa conducted and radiated emissions en 50082-1 : 1992 radiated immunity, esd and fbt zfk, zry exclusine cable (zrzp) cable: 4-cores sealed wire (o 2 signal and r- themo couple signal) and 2-cores cable (power) cable conduit: flexible type length: refer to code symbols detector: detector main unit x 1, viton o ring x 1, mounting screw (m5mm x 12) x 6, thermal sticker x 1, flow guide tube (as specified) x 1, ceramic filter x 1, cover (as specified) x 1, reference air inlet (as specified) x 1 converter: converter main unit x 1 accessories (ac250v 500ma t fuse x 1, ac250v 3.15a t fuse x 1) items to be prepared separately: (1) standard gas for calibration type zbm m nsk4-01 (2) reduction valve for standard gas (type zbd61003) (3) flowmeter type; zbd52203, 0.2 to 2l/min (for calibrating gas) cautions if combustible gas (co, h 2 etc.) exists in the measured gas, error will occur due to burning at the sensor section. the inclusion of corrosive gas (si vapor, alkaline metal, p, pb etc.) will shorten the life of the sensor. when the measured gas temperature is high (+300 c or higher), the flange should be separated from the furnace wall in order to bring the detector flange surface temperature below the specified value +125 c). the flow guide should be attached in the direction in which the gas flow to the detector decreases. when dust more than 1g/nm 3 is included in the gas, manual blow down is necessary. scope of delivery calibration gas inlet: brass joint for 1/4 inch tube. reference air inlet (option): rc1/8 or npt1/8 detector mounting: horizontal plane 45 , ambient sur- rounding air should be clean. outer dimensions: (l x max. dia.) 210mm x 100mm (detector) mass (approx.) {weight}: detector; 1.6kg flow guide tube (general-use, 1m); 5kg finish color: silver and sus metallic color oxygen converter (zry) measuring range: 0-5, 10, 25 vol% o 2 changeable by internal set pin. repeatability: 1.0% of full scale lineality: 2.0% of full scale indication: oxygen concentration; 3-digit led oxygen concentration output signal: 4 to 20ma dc (allowable load resistance: 500 ? or less) isolated output, linear fault contact output: 250v ac, 2a rating (close contact or open contact for fault should be specified when you place an order.) self-diagnoses: fault of sensor temperature, zero calibration error, span calibration error calibration method: manual calibration with key operation calibration gas: recommended calibration gas concen- tration zero gas; 1.0 to 2.0% o 2 span gas; 20.6 to 21.0% o 2 (oxygen concentration in the air) ambient temperature: ?0 to +50 c ambient humidity: 90% rh or less power supply: 90 to 220 or 230 v ac, 50/60hz construction: dust-tight, waterproof construction, nema4 (corresponding to ip65 of iec) material: aluminum die casting outer dimensions (h x w x d): 220 x 230 x 95mm mass {weight}: approx. 4.5kg (excluding cable and de- tector) finish color: munsell 6pb 3.5/10.5 (blue): cover, silver; case mounting method: mounted flush on panel
3 (converter) (exclusive-special cable) note: for connection between detector and converter, the conduit to be used should be rainproof flexible type. (detector) ( replacement detector element) code symbols - 1 pr z r z 9 2 1 345678 description connectable devices for zry conduit length cable length none 6m none 10m none 15m none 20m none 30m none 40m none 50m none 60m none 70m none 80m none 90m none 100m 6m 6m 10m 10m 15m 15m 20m 20m cable end treatment none one side (detector side) both sides types for r thermocouple p r ya yb yc yd ye yf yg yh yj yk yl ym aa bb cc dd 0 1 2 - 2 1 y ry z1 9 2 134 0 r 1 10 11 12 5678 description output signal and fault output 4 to 20ma dc, close contact 4 to 20ma dc, open contact power supply 90 to 230v ac 50/60hz (ce marking approved) b c 1 mounting method panel mounting 1 instruction manual no yes (english) y e 4 2 r zfk 9101 11213 45678 description flow guide tube flange application length none sus304 general use 300mm sus304 general use 500mm sus304 general use 750mm sus304 general use 1000mm sus316 for corrosive gas 300mm sus316 for corrosive gas 500mm sus316 for corrosive gas 750mm sus316 for corrosive gas 1000mm sus316 for high particulate 800mm sus316 for high particulate with 800mm cover protection cover without with power supply 100/115vac 50/60hz 200/220vac 50/60hz 230vac 50/60hz (ce-marking approved) cal. gas inlet for 1/4 inch tube 0 y 0 5 a 3 5 a 5 5 a 7 5 a 1 5 b 3 5 b 5 5 b 7 5 b 1 6 d 8 6 e 8 y a b y a 1 3 5 2 application general use. for corrosive gas (refuse incinerator) 2 5 reference air inlet non rc1/8 npt1/8 4 2 r zfk 9101 11213 45678 description application general use. for corrosive gas (refuse in cinerator) 2 5 power supply 100/115vac 50/60hz 200/220vac 50/60hz 230vac 50/60hz cal. gas inlet for 1/4 inch tube 1 3 5 2 note (1) dust volume is approximate value. (2) instrument quality air or bottled air is available as reference air by selecting detector with reference air inlet, when oxy gen concentration in air around sensor changes. device configuration the device to be combined differ according to the conditions of the gas to be measured. please select the devices to be combined with reference to the following table. dust less than 0.2g/m 3 [nor] less than 10g/m 3 [nor] less than 25g/m 3 [nor] ejector type protection cover no yes note fuel; gas, oil fuel: coal with manual blow down included high moisture with manual blow down temperature 600 c or less gas flow 5 to 20m/s measured gas device configuration detector type zfk r 4- zfk r 4- d zfk r 4- e application general-use (boiler) anti-corrosive use (incinerator) converter type zry zry zry 5 68 68
zfk, zry 4 converter (zry) flow guide tube system cover for retaining warmth detector zfk2 flow guide tube gas temperature. 600 c max. *3 ball valve *3 ball valve gas temperature. 600 c max. gas temperature. 600 c max. sample gas outlet sample gas outlet flow guide tube for high particulate flow guide for high particulate with cover 6mm or 4 inch tube for calibration gas (not supplied) rainproof flexible conduit. 20m max. 1 2 3 4 5 6 bule yellow white white black 4-core cable 2-core cable analog output fault contact output zirconia signal thermocouple signal sensor heater 1 2 3 4 5 6 7 8 9 10 11 12 13 14 dc4 to 20ma red white blue yellow black white cell/thermocouple output heater power supply reduction vale (zbd6) reduction valve (zbd6) *1 air supply *1 standard gas for span point (zbm) reduction valve (unnecessary when supply air pressure is 50 to 100kpa standrad gas for zero point (zbm) change valve flowmeter (zbd4) (1 to 1.5l/min) (0.2 to 0.5l/min) to detector *1 sandard gas or instrumentation air can be used in place of span gas. *2 instrument quality air or bottled air is available as reference air instead of ambient air, when oxygen concentration in air around sensor changes. *3 blow down air inlet pressure in 200 to 300kpa. *2 ref. air ac power supply red note status of fault contact output 5 digit of model b c open open open close close open power off power on and normal power on and fault configuration
5 approx. 130 approx. 65 approx. 25 approx. 118 5 proof cover (to order) filter calibration gas inlet for 1/4 inch tube. exclusive cable gland a 85 6- 6 ref. air inlet (to order) npt1/8 or rc1/8 60 36 26 45.4 80 67 black / white/ red / white/ yellow / blue 1 2 3 45 6 heater thermocouple element output 2-core wire 4-core wire exclusive-special cable external connection diagram detector (zfk2) flow guide tube 12 approx. l approx. 20 34 oxygen detector gas outlet gas inlet 8?5 mtg. holes 20 6-m5 detector side 67 130 155 3 l (m) mass 57 1 0.3 0.5 0.75 1.0 2.7 3.3 4.1 4.8 l= (to order) z approx (kg) cord 11th z f k 2 r 4 - 5 a 3 5 7 1 outline diagram (unit:mm)
zfk, zry 6 approx. 35 approx. 118 approx. 130 approx. 65 5 proof cover (to order) filter calibration gas inlet for 1/4 inch tube. exclusive cable gland 6- 6 ref. air inlet (to order) npt1/8 or rc1/8 60 black / white/ red / white/ yellow / blue 1 2 3 45 6 heater thermocouple element output 2-core wire 4-core wire exclusive-special cable external connection diagram detector (zfk5) 26 36 45.4 67 80 85 flow guide tube 12 3 approx. l approx. 40 60.5 oxygen detector gas outlet gas inlet 8- 15 mtg. holes 67 130 155 3 l (m) mass 57 1 0.3 0.5 0.75 1.0 3.3 4.5 6.1 7.6 l= (to order) z approx (kg) cord 11th z f k 5 r 4 - 5 b 3 5 7 1 67 6-m5 detctor side
7 8 - 19 mtg. hole blow down air inlet select an upper port to avoid the condensation in the piping 67 29.5 145 180 4 - rc 1/4 with plug int thd. flange: jis 5k80a ff zfk mtg. position 50 30 185 800 gas flow gas outlet packing flow guide tube (for high particulate) z f k r 4 - 6 d8 tube ( 50a sch40 ) 8 - 19 mtg. holes blow down air inlet select an upper port to avoid the condensation in the piping 67 29.5 145 180 4 - rc 1/4 with plug int thd. flange: jis 5k80a ff zfk mtg. position 50 30 (175) 800 (790) gas flow gas outlet packing z f k r 4 - 6 e8 (38) protection tube (65a sch40) tube (50a sch40) flow guide tube (for high particulate with cover)
zfk, zry 10 9 8 7 6 5 4 3 2 1 connection diagram power supply l ++ + n 5-g1/2 11 13 12 14 thermo- couple element input output signal fault contact output heater power for sensor 15 cable grand panel flush mounted 39 40 40 40 40 3.2 95 14 230 312 220 2- 9 20 72 converter (zry) information in this catalog is subject to change without notice. printed in japan head office gate city ohsaki, east tower, 11-2, osaki 1-chome, shinagawa-ku, tokyo 141-0032, japan http://www.fesys.co.jp/eng instrumentation div. international sales dept. no.1, fuji-machi, hino-city, tokyo, 191-8502 japan phone: 81-42-585-6201, 6202 fax: 81-42-585-6187 http://www.fic-net.jp/eng caution on safety *before using this product, be sure to read its instruction manual in advance.


▲Up To Search▲   

 
Price & Availability of EDSX3-119B

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X